To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C
IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy for futur
V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul
i Preface The HS1664ECH61H is a user system interface board that connects a user system for the H8SX/1663, H8SX/1664 FP-144L package to the H8SX/1650
ii Contents Section 1 Configuration... 1 Section 2 Connection P
1 Section 1 Configuration Figure 1 and table 1 show the configuration and components of the user system interface board for the FP-144L package. P
2 CAUTION Use an NQPACK144SD socket (manufactured by Tokyo Eletech Corporation) as the FP-144L-packaged IC socket on the user system. Table
3 Section 2 Connection Procedures 2.1 Connecting the User System Interface Board to the User System WARNING Always switch OFF the user system
4 To connect the board to the user system, follow the instructions below. 2.1.1 Installing the IC Socket After checking the location of pin 1 on the
5 2.1.2 Soldering the IC Socket After fastening, solder the IC socket for an FP-144L package to the user system. CAUTION Be sure to completely
6 2.1.4 Fastening the IC Socket Connector CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.05
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
7 User system interface boardUser systemPin 1Screws (M2 × 10 mm) (for fastening the board)IC socket (NQPACK144SDmanufactured by Tokyo Eletech Corpora
8 2.2 Exchanging the Spacers of the Evaluation Chip Board After connecting the user system interface board to the user system, be careful not to app
9 2.3 Connecting the User System Interface Board to the Evaluation Chip Board WARNING Observe the precautions listed below. Failure to do so
10 Connector No.UCN1 UCN1UCN2UCN2User system interface boardEvaluation Chip Board Connector No.Board Connector No.Evaluation chip board Figure 5 Co
11 2.4 Recommended Dimensions for the User System Mounting Pad (Footprint) Figure 6 shows the recommended dimensions for the mounting pad (footprint
12 2.5 Dimensions of the Evaluation Chip Board and the User System Interface Board The dimensions of the evaluation chip board and the user system i
13 2.6 Resulting Dimensions after Connecting the User System Interface Board The dimensions of the assembly after the user system interface board ha
14 2.7 Using the Emulator without Connecting User System WARNING Always switch OFF the user system and the emulator product before the USER S
15 P1SW1USER ONUSER OFF Figure 9 SW1 Jumper Socket Spacer(2.6MQ x 13 mm) Figure 10 Attaching Spacers
16 Section 3 User System Interface Circuits The following user interface circuits are required for the emulator when the user system interface boar
H8SX/1663 Group E6000H FP-144LUser System Interface BoardHS1664ECH61H User’s ManualUser’s Manual Rev.1.00 2006.06Renesas Microcomputer Development E
17 P23P27P23P27SN74CB3Q3306ASN74CB3Q3306AMCUUser system Figure 12 User System Interface Circuit (2) MCUUser system Sub-MCUP14P14SN74CB3Q3306ATXD SN
18 MCUVHC244UHC14_RESVccUser systemEPM7128EPM7128_RES47 kΩ Figure 14 User System Interface Circuit (4)
19 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual
20 ⎯ To use the crystal oscillator mounted on the evaluation chip board Install the crystal oscillator into the crystal oscillator terminals on the
21 Section 5 Points for Caution 1. Before connecting any parts or cables, make sure that the pins at the pin 1 position on both sides are correctl
22 8. When you use the emulator without connecting it to the user system, ensure that the SW1 jumper pin is inserted to [USER-OFF]. While no pin or
23 Section 6 Restrictions There are the following restrictions on emulation of the H8SX/1663 group when the user system interface board is connecte
H8SX/1663 Group E6000H FP-144LUser System Interface BoardHS1664ECH61H User's ManualPublication Date: Rev.1.00, J
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to
1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8SX/1663 Group E6000H FP-144LUser System Interface BoardREJ10J1395-0100HS1664EC
1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the cu
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy
II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufactured in accordance with published specifications and f
III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,
Comments to this Manuals