Renesas FP-144L Technical Information

Browse online or download Technical Information for Unknown Renesas FP-144L. Renesas FP-144L Technical information User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Page 2

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy for futur

Page 3 - User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Page 4

i Preface The HS1664ECH61H is a user system interface board that connects a user system for the H8SX/1663, H8SX/1664 FP-144L package to the H8SX/1650

Page 5

ii Contents Section 1 Configuration... 1 Section 2 Connection P

Page 6

1 Section 1 Configuration Figure 1 and table 1 show the configuration and components of the user system interface board for the FP-144L package. P

Page 7 - IMPORTANT INFORMATION

2 CAUTION Use an NQPACK144SD socket (manufactured by Tokyo Eletech Corporation) as the FP-144L-packaged IC socket on the user system. Table

Page 8 - DISCLAIMER

3 Section 2 Connection Procedures 2.1 Connecting the User System Interface Board to the User System WARNING Always switch OFF the user system

Page 9

4 To connect the board to the user system, follow the instructions below. 2.1.1 Installing the IC Socket After checking the location of pin 1 on the

Page 10 - SAFETY PAGE

5 2.1.2 Soldering the IC Socket After fastening, solder the IC socket for an FP-144L package to the user system. CAUTION Be sure to completely

Page 11

6 2.1.4 Fastening the IC Socket Connector CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.05

Page 12 - Preface

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Page 13 - Contents

7 User system interface boardUser systemPin 1Screws (M2 × 10 mm) (for fastening the board)IC socket (NQPACK144SDmanufactured by Tokyo Eletech Corpora

Page 14 - Section 1 Configuration

8 2.2 Exchanging the Spacers of the Evaluation Chip Board After connecting the user system interface board to the user system, be careful not to app

Page 15 - CAUTION

9 2.3 Connecting the User System Interface Board to the Evaluation Chip Board WARNING Observe the precautions listed below. Failure to do so

Page 16

10 Connector No.UCN1 UCN1UCN2UCN2User system interface boardEvaluation Chip Board Connector No.Board Connector No.Evaluation chip board Figure 5 Co

Page 17

11 2.4 Recommended Dimensions for the User System Mounting Pad (Footprint) Figure 6 shows the recommended dimensions for the mounting pad (footprint

Page 18

12 2.5 Dimensions of the Evaluation Chip Board and the User System Interface Board The dimensions of the evaluation chip board and the user system i

Page 19

13 2.6 Resulting Dimensions after Connecting the User System Interface Board The dimensions of the assembly after the user system interface board ha

Page 20

14 2.7 Using the Emulator without Connecting User System WARNING Always switch OFF the user system and the emulator product before the USER S

Page 21 - (2.6MP × 25 mm)

15 P1SW1USER ONUSER OFF Figure 9 SW1 Jumper Socket Spacer(2.6MQ x 13 mm) Figure 10 Attaching Spacers

Page 22

16 Section 3 User System Interface Circuits The following user interface circuits are required for the emulator when the user system interface boar

Page 23 - Evaluation

H8SX/1663 Group E6000H FP-144LUser System Interface BoardHS1664ECH61H User’s ManualUser’s Manual Rev.1.00 2006.06Renesas Microcomputer Development E

Page 24 - (Footprint)

17 P23P27P23P27SN74CB3Q3306ASN74CB3Q3306AMCUUser system Figure 12 User System Interface Circuit (2) MCUUser system Sub-MCUP14P14SN74CB3Q3306ATXD SN

Page 25 - Interface Board

18 MCUVHC244UHC14_RESVccUser systemEPM7128EPM7128_RES47 kΩ Figure 14 User System Interface Circuit (4)

Page 26

19 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual

Page 27

20 ⎯ To use the crystal oscillator mounted on the evaluation chip board Install the crystal oscillator into the crystal oscillator terminals on the

Page 28 - Figure 9 SW1 Jumper Socket

21 Section 5 Points for Caution 1. Before connecting any parts or cables, make sure that the pins at the pin 1 position on both sides are correctl

Page 29 - Power-supply

22 8. When you use the emulator without connecting it to the user system, ensure that the SW1 jumper pin is inserted to [USER-OFF]. While no pin or

Page 30 - User system

23 Section 6 Restrictions There are the following restrictions on emulation of the H8SX/1663 group when the user system interface board is connecte

Page 31

H8SX/1663 Group E6000H FP-144LUser System Interface BoardHS1664ECH61H User's ManualPublication Date: Rev.1.00, J

Page 32

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Page 33 - Enlarged

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8SX/1663 Group E6000H FP-144LUser System Interface BoardREJ10J1395-0100HS1664EC

Page 35

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the cu

Page 37 - User System Interface Board

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy

Page 38 - RENESAS SALES OFFICES

II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufactured in accordance with published specifications and f

Page 39 - HS1664ECH61H User’s Manual

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Comments to this Manuals

No comments