Renesas User System Interface Cable HS2655ECH61H User Manual

Browse online or download User Manual for Hardware Renesas User System Interface Cable HS2655ECH61H. Renesas User System Interface Cable HS2655ECH61H User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Page 2

i Preface Thank you for purchasing this user system interface cable (HS2655ECH61H) for the Renesas’s original microcomputer H8S/2655 group. The HS265

Page 3 - User’s Manual

ii Contents Section 1 Configuration...1 Section 2 Connection Pr

Page 4 - Cautions

1 Section 1 Configuration CAUTION Use an NQPACK128RD socket (manufactured by Tokyo Eletech Corporation) for the FP-128 package IC socket

Page 5 - IMPORTANT INFORMATION

2 Figure 1 HS2655ECH61H User System Interface Cable

Page 6 - DISCLAIMER

3 Table 1 lists the HS2655ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2655ECH61H Components No.

Page 7

4 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Page 8 - SAFETY PAGE

5 Figure 2 Connecting User System Interface Cable to Emulator Station

Page 9

6 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Page 10 - Preface

7 User systemBottom view of IC socket4 projections to apply epoxyadhesice toIC socket(Tokyo Eletech CorporationNQPACK128RD)Guide pinsPin 1 Figure 3

Page 11 - Contents

8 2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriber provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less

Page 12 - CAUTION

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Page 13

9 Figure 4 Connecting User System Interface Cable to User System

Page 14

10 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser system Figure

Page 15

11 2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system

Page 16

12 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7

Page 17

13 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Page 18

14 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided f

Page 19

15 User systemScrews (M2 x 6 mm)IC socketTokyo Eletech CorporationNQPACK128RDSocket coverMCUPin 1 Figure 9 Installing MCU to User System

Page 20

16 Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2655 group, turn on the emulator according to the procedures describ

Page 21 - 2.2.5 Fastening Cable Body

17 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Page 22 - 23.00 ± 0.15

18 6. The JP1 jumper socket is used for testing. Do not remove the inserted jumper pin. JP1 Figure 12 JP1 Jumper Socket

Page 23

H8S/2655 Group QFP-128User System Interface CableHS2655ECH61H User’s ManualUser’s Manual Rev.4.0 2004.01Renesas Microcomputer Development Environmen

Page 24

H8S/2655 Group QFP-128User System Interface Cable HS2655ECH61H User's ManualPublication Date: Rev.4.00, Janu

Page 25

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8S/2655 Group QFP-128User System Interface CableREJ10B0086-0400HHS2655ECH61H Us

Page 26 - Screws (M2 x 6 mm)

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better an

Page 27

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Page 28 - Section 5 Notice

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and f

Page 29 - Figure 12 JP1 Jumper Socket

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Page 30 - User System Interface Cable

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Page 31 - HS2655ECH61H User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Comments to this Manuals

No comments