(b) Window Trace Function
Memory access in the specified range can be acquired by trace.
Two memory ranges can be specified for channels A and B. The read, write, or read/write
cycle can be selected as the bus cycle for trace acquisition.
Setting Method:
(i) Select the [Channel A] and [Channel B] check boxes in the [AUD function] group
box of the [Trace mode] page. Each channel will become valid.
(ii) Open the [Window trace] page and specify the bus cycle and memory range that are to be
set for each channel.