Renesas H8/2318 Series Technical Information

Browse online or download Technical Information for Unknown Renesas H8/2318 Series. Renesas H8/2318 Series Technical information User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Page 2

Figure 2 Connecting User System Interface Cable to Emulator Station 4

Page 3 - User’s Manual

2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER S

Page 4 - Cautions

6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B/TFP-100B package

Page 5 - Preface

Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on the user system with the four screws (M2.6 x 12 mm; wi

Page 6 - Contents

2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigs.RemovingUser systemFigure 4

Page 7

2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with

Page 8

2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mmT

Page 9

2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head

Page 10

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver

Page 11

Figure 8 Installing MCU to User System 13

Page 12 - CAUTION

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Page 13 - User system

Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described

Page 14 - 2.2.5 Fastening Cable Body

Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable

Page 15 - 0.50 ± 0.05

Figure 11 P1 Short Connector 16

Page 16 - Tolerance: ±0.5 mm

H8/2318 Series FP-100B/TFP-100BUser System Interface Cable (HS2318ECH61H) for E6000 EmulatorUser’s ManualUser’s ManualRev.2.0 2003.04

Page 17

Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel

Page 18

i Preface Thank you for purchasing this user system interface cable (HS2318ECH61H) for the Renesas’s original microcomputer H8/2318 series. The HS231

Page 19

ii Contents Section 1 Configuration...1 Section 2 Connection P

Page 20 - Figure 9 Oscillator Circuit

Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/TFP- 100B

Page 21 - Section 5 Notice

2 Table 1 lists the HS2318ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2318ECH61H Components No.

Page 22

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. F