Section 2 User System Interface
All user system interface signals are directly connected to the MCU in the E6000 with no buffering
except for those listed below which are connected to the MCU through control circuits:
NMI
RESET
MD2, MD1, MD0
XTAL
EXTAL
OSC1
OSC2
STBY
WAIT
2.1 Signal Protection
All user system interface signals are protected from over- or under-voltage by use of diode arrays
except for the AVcc and Vref.
The Vcc pins (except for the AVcc pin) at the head of the user system interface cable are
connected together. The E6000 monitors the voltage level of the Vcc pins and displays the power-
supply status in the Status Window.
2.2 User System Interface Circuits
The interface circuit between the MCU in the E6000 emulator and the user system has a signal
delay of about 8 ns due to the user system interface cable. And high-impedance signals will be
pulled up to the high level by pull-up resistors. When connecting the E6000 emulator to a user
system, adjust the user system hardware to compensate for propagation delays.
The following diagrams show the interface signal circuits