3.3 User System Interface Circuit
3.3.1 User System Interface Circuit
The circuits that interface the MCU in the emulator to the user system include buffers and resistors. When
connecting the emulator to a user system, adjust the user system hardware compensating for FANIN, FANOUT,
and propagation delays.
The AC timing values when using the emulator are shown in table 3.2.
Note: The values with the emulator connected, in table 3.2, are measurements for reference and are not
guaranteed values.
Table 3.2 Bus Timing when Using the Emulator (Bus Clock: 50.0 MHz)
MCU Specifications (ns) Values with Emulator Connected (ns)
Item Min Max Min Max
tRDS 15 16
tACC tcyc x (n + 2) – 35
(n is the number of
waits)
tcyc x (n + 2) – 37
(n is the number of
waits)
The basic bus cycle (software wait) is shown in figure 3.2. The user system interface circuits connected to the
user system are shown in figures 3.3 to 3.8.