H8S/2214 Series TBP-112 User System Interface Cable (HS2214ECB61H) for E6000 Emulator User’s Manual HS2214ECB61HE(C)
6 (4) Notes on soldering the IC socket a) The IC socket is larger than the actual IC package; therefore, refer to figure 7 for the installation of o
7 CAUTION 1. Never dip the IC socket in flux or use wash to clean the IC socket. This is because flux may remain inside the IC socket du
2.2.2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TBP-112 package on the user
2.2.3 Fastening Cable Head CAUTION 1. Use the screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or
2. Next, fasten screws to ② and ④ a little, so that four screw holes are aligned. Then, each screw should be tightened a little at a time, alternati
2.2.4 Fastening Cable Body Connect the cable body to the cable head. Figure 6 Fastening Cable Body 11
2.3 Recommended Dimensions for User System Mount Pad Figure 7 shows the recommended dimensions for the mount pad (footprint) for the user system with
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 8. Figure 8 Dime
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head
15 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a provided screwdriver.
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel
Figure 10 Installing MCU to User System 16
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2214 series, turn on the emulator according to the procedures described
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable
i Preface Thank you for purchasing this user system interface cable (HS2214ECB61H) for the Renesas’s original microcomputer H8S/2214series. The HS221
ii Contents Section 1 Configuration...1 Section 2 Connection Pr
Section 1 Configuration CAUTION Use an CSPACK112A1110H01 socket (socket (manufactured by Tokyo Eletech Corporation) for the TBP-112 packa
2 Table 1 lists the HS2214ECB61H components. Please make sure you have all of these components when unpacking. Table 1 HS2214ECB61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. F
Figure 2 Connecting User System Interface Cable to Emulator Station 4
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER S
Comments to this Manuals