Maintenance and Test Procedures
40
Access Control Design Guide
LED10 (DC COMMS) – Illuminated when an external door or alarms controller is connected.
LED11/12/13/14 (RDR 1/2/3/4) – Illuminated when the reader is connected properly.
LED19 (NIC1 Rx) – Illuminated when receiving data from the plug-in COM D port.
LED20 (NIC1 Tx) – Illuminated when transmitting data to the plug-in COM D port.
LED21 (NIC2 Rx) – Illuminated when receiving data from the plug-in COM E port.
LED22 (NIC2 Tx) – Illuminated when transmitting data to the plug-in COM E port.
LED15/23/27/39 (RX) – Illuminated when receiving data from a 20mA reader (off for Wiegand).
LED16/24/28/40 (BY) – Illuminated when the bypass relay is energized.
LED17/25/29/41 (TX) – Illuminated when transmitting data to a 20mA reader (off for Wiegand).
LED18/26/30/42 (RL) – Illuminated when the release relay is energized.
LED31/33 (COMA/B TX) – Flashes when there is a database unit connected to the COM A/B port.
Otherwise, the LED is not illuminated.
LED32/34 (COMA/B RX) – Flashes when there is a database unit connected to the COM A/B port.
Otherwise, the LED is permanently illuminated.
LED35 (RS232 TX) – Flashes when the on-board RS232 port (TB13) is transmitting data. Otherwise, the
LED is not illuminated.
LED36 (RS232 RX) – Flashes when the on-board RS232 port (TB13) is receiving data. Otherwise, the LED
is not illuminated.
LED37 (RS485 TX) – Illuminated when transmitting data to an external door or alarms controller.
LED38 (RS485 RX) – Illuminated when receiving data from an external door or alarms controller.
LEDs on the 8DBC and 8DC
LED1/5/9/13/39/43/55/59 (RECEIVE or RX) – Illuminated when receiving data from a 20mA reader (off for
Wiegand).
LED2/6/10/14/40/44/56/60 (TRANSMIT or TX) – Illuminated when transmitting data to a 20mA reader (off
for Wiegand).
LED3/7/11/15/41/45/57/61 (BYPASS or BY) – Illuminated when the bypass relay is energized.
LED4/8/12/16/42/46/58/62 (RELEASE or RL) – Illuminated when the release relay is energized.
LED47/49 (COMA/B TX) – Flashes when there is a database unit connected to the COM A/B port.
Otherwise, the LED is not illuminated.
LED48/50 (COMA/B RX) – Flashes when there is a database unit connected to the COM A/B port.
Otherwise, the LED is permanently illuminated.
LED51 (RS232 TX) – Flashes when the on-board RS232 port (TB15) is transmitting data. Otherwise, the
LED is not illuminated.