To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C
Emulator stationExpansion I/O boardE6000Cable body connectorUser system interface cableUSERINTERFACECABLE6000EMULATOE6000 Figure 2 Connecting User S
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER S
Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. User systemIC socket(NQPACK100SE manufactured by Toky
7 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TFP-144 package on the u
Fasten the user system interface cable head to the IC socket for an TFP-144 package on the user system with the four screws (M2.0 x 10 mm) provided.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headUnfastening jigPush the unfastening jigRemovingUser systemF
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dime
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head
13 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a screwdriver whose head m
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
Figure 9 Installing MCU to User System 14
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2148 series, turn on the emulator according to the procedures described
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable
H8S/2169Series TFP-144User System Interface Cable (HS2169ECN61H) for E6000 EmulatorUser’s ManualUser’s Manual
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel
i Preface Thank you for purchasing this user system interface cable (HS2169ECN61H) for the Renesas’s original microcomputer H8S/2169 series. The HS21
ii Contents Section 1 Configuration...1 Section 2 Connection P
Section 1 Configuration CAUTION Use an NQPACK144SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-144 package IC socket on
2 Table 1 lists the HS2169ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2169ECN61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Expansion I/O board WARNING Observe the precautions listed below.
Comments to this Manuals