Renesas H8S/2615 Series Technical Information

Browse online or download Technical Information for Unknown Renesas H8S/2615 Series. Renesas H8S/2615 Series Technical information [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Page 2

IV SAFETY PAGE READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference

Page 3 - To all our customers

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emula

Page 4 - Cautions

VI CAUTION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

Page 5 - User’s Manual

i Preface Thank you for purchasing the H8S/2628, H8S/2615 series E6000 emulator. The H8S/2628, H8S/2615 series E6000 emulator (hereafter referred

Page 6

ii Contents Section 1 Overview...1 1.1 Environment Condit

Page 7 - IMPORTANT INFORMATION

iii Figures Figure 2.1 Default User System Interface Circuit...4 Figure 2.2 Us

Page 8 - DISCLAIMER

1 Section 1 Overview The H8S/2628, H8S/2615 series E6000 emulator (hereafter referred to as the E6000) is an efficient software and hardware devel

Page 9

2 Table 1.3 H8S/2615 Series MCU and User System Interface Cable No. MCU Type Number Package E6000 User System Interface Cable 1 HD64F2615 80-pi

Page 10 - SAFETY PAGE

3 Section 2 User System Interface All user system interface signals are directly connected to the MCU in the E6000 with no buffering except for t

Page 11

4 Default: 47 kUser system interface cableMCU47 VccΩΩ Figure 2.1 Default User System Interface Circuit Mode Pins (MD2, MD1 and MD0), NMI, STBY and

Page 12 - CAUTION

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Page 13 - Preface

5 AN0-AN15, AVcc, AVss and Vref: User system interface cableUser system interface cableH8S/2628 seriesH8S/2615 seriesMCUMCUAVccVrefAVss0.022 Fµ0.

Page 14 - Contents

6 Section 3 Notes on Use 3.1 I/O Register Differences between Actual MCU and E6000 In the E6000, one evaluation chip emulates several types of MC

Page 15 - Figures

7 3.6 Procedure for Applying the Power When the user system is connected to the emulator, apply the power of the user system and then start the emu

Page 16 - Section 1 Overview

8 Section 4 HDI Parameters 4.1 Address Areas Table 4.1 lists the parameters for address areas (Area) that can be specified with HDI command line i

Page 17

9 4.2 Access Status Table 4.2 lists the parameters for access status (Status) that can be specified with HDI command line interface or displayed as

Page 18 - 2.1 Signal Protection

10 4.3 I/O Modules Table 4.3 lists the parameters for I/O module selection in the custom setting of the HDI Configuration window. Table 4.3 I/O Mod

Page 19 - PC0-PC7:

11 Section 5 Diagnostic Test Procedure This section describes the diagnostic test procedure using the E6000 test program. 5.1 System Set-Up for T

Page 20 - User system

12 5.2 Diagnostic Test Procedure Using the Test Program Insert the CD-R (HS2628EPI61SR supplied with the E6000) into the CD-ROM drive of the host c

Page 21 - Section 3 Notes on Use

13 The following messages are displayed during the test. There are 19 steps in this test. The following messages are displayed during the test. Mes

Page 22

14 1) Test Register A) IDR0 Register ...OK B) PAGE Register ...OK C

Page 23 - Section 4 HDI Parameters

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Page 24 - 4.2 Access Status

15 C) Decode Test page[H'000 - H'04f](Upper 32 K) ...OK Shows the results of decoding test for the trace RAM (last half) in the E6

Page 25 - 4.3 I/O Modules

16 9) Test Keybreak A) Key Break ...OK Shows the check results for the forced break controlling circuits

Page 26

17 15) Test Emulation Monitor A) EMA23-EMA0 ...OK B) ACST2-ACST0 ...

Page 27

18 19) Test H8S/2628 Register Read/Write A) Register Read ...OK B) Register Read/Write Test ...

Page 28

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products bett

Page 29

H8S/2628, H8S/2615 SeriesE6000 Emulator HS2628EPI61HSupplementary InformationUser’s Manual Rev.3.0 2003.03

Page 30

Cautions 1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other in

Page 31

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future

Page 32

II LIMITED WARRANTY Hitachi warrants its emulator products to be manufactured in accordance with published specifications and free from defec

Page 33

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so

Comments to this Manuals

No comments