101
5.6.3 On-Emulator Break
Overview: On-emulator break functions are implemented by dedicated hardware in the E6000H
station. The on-emulator break conditions have four channels (On Emulator Break 1 to 4). On-
emulator break occurs when all of the specified conditions (an AND condition) are satisfied.
Table 5.21 On-Emulator Break Conditions
Condition Description
Address bus Satisfied when the value on the address bus matches the
specified value.
Data bus Satisfied when the value on the data bus matches the specified
value.
Bus/Area Satisfied when the specified access type, bus status, and
read/write cycle conditions are matched.
When no condition is set, all bus cycles, including program-fetch
cycles, satisfy the condition.
External probe Satisfied when the external probe (PRB) signal levels match a
specification.
External interrupt signal Satisfied when the external interrupt signal levels match a
specification.
Satisfaction count The break occurs when the above conditions are satisfied the
specified number of times.
Comments to this Manuals