Renesas Single-Chip Microcomputer M37531T-ADS User Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
M38000T2-CPE User’s Manual 3. Usage (How to Use the Emulator Debugger)
REJ10J0301-0400 Rev.4.00 March 01, 2006
Page 45 of 78
3. Example of the trace window display
Bus display (BUS)
Explanation of the trace window (bus
display)
The following explains the displayed contents, from left to
right.
- Address
Shows the status of the address bus.
- Data
Shows the status of the data bus.
- SYNC
Output during instruction opcode fetch, this signal
assumes the value 1 when opcode is fetched. If the
displayed Sync value is enclosed in parentheses as in (1),
it means a dummy Sync, in which case the instruction in
that line actually is not executed. If not accessed, the
value is displayed as “-“.
- Read
Indicates the data bus state. This signal determines the
direction of the data bus. When in a Read state, it
indicates the value 0.
- Write
Indicates the data bus state. This signal determines the
direction of the data bus. When in a Write state, it
indicates the value 0.
Disassemble display (DIS)
Source display (SRC)
Data access display (DATA)
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 77 78

Comments to this Manuals

No comments