Page 72 of 78
5.2 When the Emulator Debugger Does Not Start Up Properly
(1) When the LEDs of the M38000T2-CPE Do Not Display Normally
Table 5.1 Errors LEDs show and their checkpoints (2)
: ON
: OFF
: Blinking
Example
POWER CLOCK RESET RUN
Problem & Remedy
The emulator system is not working properly.
- If the SAFE LED is blinking, startup the emulator debugger and download the
firmware.
- Check that the emulator is powered.
- The emulator may be damaged. Contact your local distributor.
The user system is not powered or the target status cables are not connected properly.
- Check that the emulator is powered.
- Check that the VCC and GND clips of target status cables are connected properly.
- Check that the emulator MCU type selection switch is set properly.
- Check that the probe board and the user system are connected properly.
The emulator MCU type selection switch is not set properly.
- Check that the VCC and GND clips of target status cables are connected properly.
- Check that the probe board and the user system are connected properly.
The target status cables are not connected properly.
- Check that the VCC and GND clips of target status cables are connected properly.
The reset command is not executed properly.
- Check that the reset pin is not held "H".
- Check that the "H" output type reset IC is not used in the reset circuit. With this
emulator, the "H" output type reset IC cannot be used.
- Check that the RESET clip of a target status cable is connected properly.
The internal clock ø output is not executed properly.
- Check that the power supply voltage of the user system is within the MCU's specified
range.
- Check that the oscillating frequency of the user system is within the MCU's specified
range.
The reset command cannot be canceled properly.
- Check that the reset pin is not held "L".
- Check that the pullup resistor of about 10 k is connected to the reset circuit.
Others
The emulator system is not working properly.
- The emulator may be damaged. Contact your local distributor