M38000T2-CPE User’s Manual 4. Hardware Specifications
REJ10J0301-0400 Rev.4.00 March 01, 2006
Page 51 of 78
4.2.1 Operating Condition for the 38000 Series
(1) M38049RLSS
Applicable group
3803, 3803H and 3804 Groups
Operating supply voltage [V]
Operating frequency f(XIN)[MHz]
Operating mode f(φ)=f(XIN)/2
* Be sure to use the emulator MCU M38049RLSS.
* The evaluation at a voltage lower than 2.7 V and higher
than 5.0 V is not available in combination with the M38000T2-CPE.
For the specification of the mass-produced
MCUs, be sure to check the data sheet of your MCU.
Guaranteed operating range of M 38000T2-CPE
2005-09-26 Rev.1.10
Guaranteed operating range of 3803(Spec.H)
Guaranteed operating range of 3803(standard) and 3804
Operating supply voltage [V]
Operating frequency f(XIN)[MHz]
Operating mode f(φ)=f(XIN)/8
8.4
2.1
12.5
2.0
5.0 5.52.7 4.5
16.8
4.0
6.3
8.4
12.5
16.8
1.8 2.7 4.0 5.0 5.52.2 4.5
Figure 4.1 Operating conditions of the M38049RLSS
(2) M38227RFS
Applicable group
3822,3822M,3822H,3822A Group
Operating supply voltage [V]
Operating frequency f(XIN) [MHz]
Operating mode f(φ)=f(XIN)/2
* Be sure to use the emulator MCU M38227RFS.
* The evaluation at a voltage lower than 2.5 V and higher
than 5 V is not available in combination with the M38000T2-CPE.
For the specification of the mass-produced
MCUs, be sure to check the data sheet of your MCU .
Guaranteed operating range of M38000T2-CPE
2006-03-20 Rev.1.20
Guaranteed operating range of 3822M
Guaranteed operating range of 3822
Operating supply voltage [V]
Operating frequency f(XIN) [MHz]
Operating mode f(φ)=f(XIN)/8
8.0
4.0
10.0
2.0 4.0 5.0 5.52.5 4.5
8.0
6.0
3.0 5.0 5.51.8 2.2
10.0
2.0 2.5
Guaranteed operating range of 3822H
Guaranteed operating range of 3822A
* When debugging the 3822M,3822H and 3822A Group MCU using the M38227RFS,
be concerned about the difference of specifications of the MCUs .
Figure 4.2 Operating conditions of the M38227RFS
IMPORTANT
Note on the M38227RFS:
z The M38227RFS is a standard type MCU. When debugging the 3822 Group M, H and A version MCUs using
the M38227RFS, be concerned about the difference of specifications of the MCUs.